Product Details:
Payment & Shipping Terms:
|
Input Range: | 100 ~ 240Vac, 50 / 60Hz | Power Range: | 15 ~ 24W |
---|---|---|---|
Certificates: | UL/cUL 60601-1, TUV EN 60601-1, CB IEC 60601-1, FCC, CE, PSE, UKCA | Application: | Breath Detectors/testers, ECG, EEG, Portable Medical Devices, Medical Tablets, Digital Blood Pressure Monitors, Etc. |
MTBF: | 100,000 Calculated Hours | Case Size: | 60.5L X 39W X 34H(mm) |
IEC/EN 60601 RCM Certified Medical Grade Switching Power Supply | 12V 24V 5V 36V AC Adapter with AU Plug
The IEC/EN 60601 RCM Certified Medical Grade Switching Power Supply is a reliable and efficient power solution designed specifically for medical applications. This versatile AC adapter supports multiple output voltages, including 12V, 24V, 5V, and 36V, and features an AU plug for seamless integration in Australian healthcare environments.
This medical-grade switching power supply is a critical component for healthcare providers seeking safe, efficient, and versatile power solutions for their medical devices.
• Power Range: 15~24W
• Universal AC Input 100~240 VAC
• Frequency: 50~60Hz
• AC Plug type: U:USA, E:EU, K:UK, A: AU
• Output voltage available from 5~48 VDC
• 2 x MOPP Compliance, IEC/EN60601-1 Approval
• LPS Compliance
• Protections: Short circuit / Over voltage / Over current
• Energy Efficiency Level VI
• No Load Power Consumption ≤ 0.1W
• MTBF > 100,000 hours
• Safety: UL/cUL, UL60601, TUV EN60601, CB 60601, CE, FCC
• All models meet RoHS and WEEE
• Dimension(L x W x H): 60.5L x 39W x 34H(mm)
• Weight: 120g
Model NO. | MAX OUTPUT POWER | OUTPUT VOLTAGE | MIN LOAD | MAX LOAD | LOAD REGULATION | LINE REGULATION | RIPPLE & NOISE |
APM19AA | 15W | 5-8V | 0A | 3.0A | ±5% | ±1% | 100mV |
APM19AB | 20W | 9-13V | 0A | 2.0A | ±5% | ±1% | 180mV |
APM19AC | 20W | 14-19V | 0A | 1.42A | ±5% | ±1% | 200mV |
APM19AD | 20W | 20-27V | 0A | 1.0A | ±5% | ±1% | 250mV |
APM19AE | 20W | 28-35V | 0A | 0.71A | ±5% | ±1% | 280mV |
APM19AF | 20W | 36-48V | 0A | 0.55A | ±5% | ±1% | 360mV |
APM19AG | 18W | 5-8V | 0A | 3.0A | ±5% | ±1% | 100mV |
APM19AH | 24W | 9-13V | 0A | 2.0A | ±5% | ±1% | 180mV |
APM19AJ | 24W | 14-19V | 0A | 1.71A | ±5% | ±1% | 200mV |
APM19AK | 24W | 20-27V | 0A | 1.2A | ±5% | ±1% | 250mV |
APM19AL | 24W | 28-35V | 0A | 0.85A | ±5% | ±1% | 280mV |
APM19AM | 24W | 36-48V | 0A | 0.66A | ±5% | ±1% | 360mV |
NOTED: | |||||||
1 : Ripple & Noise is measured by using 20MHz bandwidth limited oscilloscope and terminated each output with a 0.1uF ceramic capacitor & parallel with 47uF aluminum capacitor at full load and nominal line. | |||||||
2 : Line regulation is defined by changing ±10% of input voltage from nominal line at rated load. | |||||||
3 : Max. Power (W) = Vo x Io |