Product Details:
Payment & Shipping Terms:
|
| Input: | 100 ~ 240Vac, 50 / 60Hz | Power Range: | 24W Max |
|---|---|---|---|
| Certificates: | UL/cUL 60601-1, TUV EN 60601-1, CB IEC 60601-1, FCC, CE, PSE, UKCA | Application: | Breath Detectors/testers, ECG, EEG, Portable Medical Devices, Medical Tablets, Digital Blood Pressure Monitors, Etc. |
| MTBF: | 100,000 Calculated Hours | Case Size: | 60.5L X 39W X 26.5H (mm) |
UL 60601 Certified Medical Power Adapter 12V 2A 24V 1A 9V US Plug for Ophthalmic Tonometers Eye Pressure Monitors
UL/IEC 60601 certified medical-grade power adapter delivering precise triple voltage output: 12V 2A, 24V 1A, and 9V with US plug compatibility specifically engineered for ophthalmic tonometers and eye pressure monitoring systems. This hospital-grade power supply features medical isolation barriers, over-voltage protection, and electromagnetic compatibility to ensure accurate intraocular pressure measurements and safe operation in clinical environments. Designed for optometry clinics, ophthalmology practices, and eye care facilities, the adapter provides stable voltage regulation and thermal protection for continuous diagnostic use where power reliability directly impacts patient eye health assessments and treatment accuracy. FCC certified and built to meet stringent medical safety standards for professional healthcare applications requiring certified performance in sensitive ophthalmic diagnostic equipment.
• Power Range: 24W max
• Universal AC Input 100~240 VAC
• Frequency: 50~60Hz
• AC Plug type: U:USA, E:EU, K:UK, A: AU
• Output voltage available from 5~48 VDC
• 2 x MOPP Compliance, IEC/EN60601-1 Approval
• LPS Compliance
• Protections: Short circuit / Over voltage / Over current
• Energy Efficiency Level VI
• No Load Power Consumption ≤ 0.1W
• MTBF > 100,000 hours
• Safety: UL/cUL, UL60601, TUV EN60601, CB 60601, CE, FCC
• All models meet RoHS and WEEE
• Dimension(L x W x H): 60.5L x 39W x 26.5H (mm)
• Weight: 120g
| Model NO. | MAX OUTPUT POWER | OUTPUT VOLTAGE | MIN LOAD | MAX LOAD | LOAD REGULATION | LINE REGULATION | RIPPLE & NOISE |
| APM24UA | 15W | 5-8V | 0A | 3.0A | ±5% | ±1% | 100mV |
| APM24UB | 20W | 9-13V | 0A | 2.0A | ±5% | ±1% | 180mV |
| APM24UC | 20W | 14-19V | 0A | 1.42A | ±5% | ±1% | 200mV |
| APM24UD | 20W | 20-27V | 0A | 1.0A | ±5% | ±1% | 250mV |
| APM24UE | 20W | 28-35V | 0A | 0.71A | ±5% | ±1% | 280mV |
| APM24UF | 20W | 36-48V | 0A | 0.55A | ±5% | ±1% | 360mV |
| APM24UG | 18W | 5-8V | 0A | 3.0A | ±5% | ±1% | 100mV |
| APM24UJ | 24W | 9-13V | 0A | 2.0A | ±5% | ±1% | 180mV |
| APM24UK | 24W | 14-19V | 0A | 1.71A | ±5% | ±1% | 200mV |
| APM24UL | 24W | 20-27V | 0A | 1.2A | ±5% | ±1% | 250mV |
| APM24UM | 24W | 28-35V | 0A | 0.85A | ±5% | ±1% | 280mV |
| APM24UN | 24W | 36-48V | 0A | 0.66A | ±5% | ±1% | 360mV |
| NOTED: | |||||||
| 1 : Ripple & Noise is measured by using 20MHz bandwidth limited oscilloscope and terminated each output with a 0.1uF ceramic capacitor & parallel with 47uF aluminum capacitor at full load and nominal line. | |||||||
| 2 : Line regulation is defined by changing ±10% of input voltage from nominal line at rated load. | |||||||
| 3 : Max. Power (W) = Vo x Io | |||||||
![]()