Product Details:
Payment & Shipping Terms:
|
| Input: | 100 ~ 240Vac, 50 / 60Hz | Power Range: | 15 ~ 24W |
|---|---|---|---|
| Certificates: | UL/cUL 60601-1, TUV EN 60601-1, CB IEC 60601-1, FCC, CE, PSE, UKCA | Application: | Breath Detectors/testers, ECG, EEG, Portable Medical Devices, Medical Tablets, Digital Blood Pressure Monitors, Etc. |
| MTBF: | 100,000 Calculated Hours | Case Size: | 60.5L X 39W X 34H(mm) |
EN 60601 Certified Medical Power Adapter 12V 2A 24V 1A 9V US Plug for Laser Therapy Hair Removal Equipment Devices
EN/IEC 60601 certified medical-grade power adapter delivering triple voltage output: 12V 2A, 24V 1A, and 9V specifically engineered for professional laser therapy and hair removal systems. This US plug adapter features medical-grade isolation barriers, over-voltage protection, and electromagnetic compatibility to ensure safe operation with sensitive aesthetic equipment. Designed for clinical environments including dermatology clinics, medical spas, and cosmetic treatment centers, the power supply provides stable voltage regulation for consistent laser performance and treatment accuracy. Built with thermal protection and precision engineering to maintain device calibration during extended sessions, this certified adapter meets stringent safety standards for professional healthcare applications where power reliability directly impacts patient treatment outcomes and equipment longevity in aesthetic medical procedures.
• Power Range: 15~24W
• Universal AC Input 100~240 VAC
• Frequency: 50~60Hz
• AC Plug type: U:USA, E:EU, K:UK, A: AU
• Output voltage available from 5~48 VDC
• 2 x MOPP Compliance, IEC/EN60601-1 Approval
• LPS Compliance
• Protections: Short circuit / Over voltage / Over current
• Energy Efficiency Level VI
• No Load Power Consumption ≤ 0.1W
• MTBF > 100,000 hours
• Safety: UL/cUL, UL60601, TUV EN60601, CB 60601, CE, FCC
• All models meet RoHS and WEEE
• Dimension(L x W x H): 60.5L x 39W x 34H(mm)
• Weight: 120g
| Model NO. | MAX OUTPUT POWER | OUTPUT VOLTAGE | MIN LOAD | MAX LOAD | LOAD REGULATION | LINE REGULATION | RIPPLE & NOISE |
| APM19UA | 15W | 5-8V | 0A | 3.0A | ±5% | ±1% | 100mV |
| APM19UB | 20W | 9-13V | 0A | 2.0A | ±5% | ±1% | 180mV |
| APM19UC | 20W | 14-19V | 0A | 1.42A | ±5% | ±1% | 200mV |
| APM19UD | 20W | 20-27V | 0A | 1.0A | ±5% | ±1% | 250mV |
| APM19UE | 20W | 28-35V | 0A | 0.71A | ±5% | ±1% | 280mV |
| APM19UF | 20W | 36-48V | 0A | 0.55A | ±5% | ±1% | 360mV |
| APM19UG | 18W | 5-8V | 0A | 3.0A | ±5% | ±1% | 100mV |
| APM19UH | 24W | 9-13V | 0A | 2.0A | ±5% | ±1% | 180mV |
| APM19UJ | 24W | 14-19V | 0A | 1.71A | ±5% | ±1% | 200mV |
| APM19UK | 24W | 20-27V | 0A | 1.2A | ±5% | ±1% | 250mV |
| APM19UL | 24W | 28-35V | 0A | 0.85A | ±5% | ±1% | 280mV |
| APM19UM | 24W | 36-48V | 0A | 0.66A | ±5% | ±1% | 360mV |
| NOTED: | |||||||
| 1 : Ripple & Noise is measured by using 20MHz bandwidth limited oscilloscope and terminated each output with a 0.1uF ceramic capacitor & parallel with 47uF aluminum capacitor at full load and nominal line. | |||||||
| 2 : Line regulation is defined by changing ±10% of input voltage from nominal line at rated load. | |||||||
| 3 : Max. Power (W) = Vo x Io | |||||||
![]()