Product Details:
Payment & Shipping Terms:
|
| Input Range: | 100 ~ 240Vac, 50 / 60Hz | Power Range: | 15 ~ 24W |
|---|---|---|---|
| Certificates: | UL/cUL 60601-1, TUV EN 60601-1, CB IEC 60601-1, FCC, CE, PSE, UKCA | Application: | Breath Detectors/testers, ECG, EEG, Portable Medical Devices, Medical Tablets, Digital Blood Pressure Monitors, Etc. |
| MTBF: | 100,000 Calculated Hours | Size: | 66.5L X 26W X 45.5H(mm) |
UL 60601 Certified Medical Power Adapter 12V 2A 24V 1A 9V US Plug for Portable Ultrasound Diagnostic Equipment Devices
UL/IEC 60601 certified medical-grade power adapter delivering triple output configuration: 12V 2A, 24V 1A, and 9V charging with US plug compatibility specifically engineered for portable ultrasound diagnostic systems. This hospital-grade power supply features medical isolation barriers, over-voltage protection, and electromagnetic compatibility to ensure uninterrupted imaging performance in clinical environments. Designed for radiology departments, emergency medical services, and point-of-care diagnostics, the adapter provides stable power for ultrasound probes, transducers, and imaging units requiring certified safety standards. Built with thermal protection and precise voltage regulation to maintain image quality and diagnostic accuracy during critical examinations, this FCC-certified adapter meets stringent medical safety requirements for professional healthcare use where reliable power directly impacts patient diagnostics and clinical outcomes.
• Power Range: 15~24W
• Universal AC Input 100~240 VAC
• Frequency: 50~60Hz
• AC Plug type: U:USA, E:EU, K:UK, A: AU
• Output voltage available from 5~48 VDC
• 2 x MOPP Compliance, IEC/EN60601-1 Approval
• LPS Compliance
• Protections: Short circuit / Over voltage / Over current
• Energy Efficiency Level VI
• No Load Power Consumption ≤ 0.1W
• MTBF > 100,000 hours
• Safety: UL/cUL, UL60601, TUV EN60601, CB 60601, CE, FCC
• All models meet RoHS and WEEE
• Dimension(L x W x H): 66.5L x 26W x 45.5H(mm)
• Weight: 120g
| Model NO. | MAX OUTPUT POWER | OUTPUT VOLTAGE | MIN LOAD | MAX LOAD | LOAD REGULATION | LINE REGULATION | RIPPLE & NOISE |
| APM19UA | 15W | 5-8V | 0A | 3.0A | ±5% | ±1% | 100mV |
| APM19UB | 20W | 9-13V | 0A | 2.0A | ±5% | ±1% | 180mV |
| APM19UC | 20W | 14-19V | 0A | 1.42A | ±5% | ±1% | 200mV |
| APM19UD | 20W | 20-27V | 0A | 1.0A | ±5% | ±1% | 250mV |
| APM19UE | 20W | 28-35V | 0A | 0.71A | ±5% | ±1% | 280mV |
| APM19UF | 20W | 36-48V | 0A | 0.55A | ±5% | ±1% | 360mV |
| APM19UG | 18W | 5-8V | 0A | 3.0A | ±5% | ±1% | 100mV |
| APM19UH | 24W | 9-13V | 0A | 2.0A | ±5% | ±1% | 180mV |
| APM19UJ | 24W | 14-19V | 0A | 1.71A | ±5% | ±1% | 200mV |
| APM19UK | 24W | 20-27V | 0A | 1.2A | ±5% | ±1% | 250mV |
| APM19UL | 24W | 28-35V | 0A | 0.85A | ±5% | ±1% | 280mV |
| APM19UM | 24W | 36-48V | 0A | 0.66A | ±5% | ±1% | 360mV |
| NOTED: | |||||||
| 1 : Ripple & Noise is measured by using 20MHz bandwidth limited oscilloscope and terminated each output with a 0.1uF ceramic capacitor & parallel with 47uF aluminum capacitor at full load and nominal line. | |||||||
| 2 : Line regulation is defined by changing ±10% of input voltage from nominal line at rated load. | |||||||
| 3 : Max. Power (W) = Vo x Io | |||||||
![]()